BEKO Technologies Products
BEKO Dryer Systems
RA Non-cycling Refrigerant Dryers

Flow Rate
10 - 480 scfm
Maximum Inlet Air Temperature
130 °F
Maximum Inlet Operating Pressure
10 - 50: 232 psig
75 - 480: 200 psig
Standard Outlet Pressure Dew Point | ISO 8573-1:2010 Air Quality Class
≤ 37-45 °F
Class 4-5
Standard Condensate Drain | Optional
Timer Solenoid
BEKOMAT®
Available Options
3-valve bypass, Cover3More Extended Warranty
Energy Saving Refrigerant Dryers

Flow Rate
20 - 500 scfm
Maximum Inlet Air Temperature
160 °F
Maximum Inlet Operating Pressure
20 - 50: 232 psig
75 - 500: 200 psig
Standard Outlet Pressure Dew Point | ISO 8573-1:2010 Air Quality Class
≤ 37-45 °F
Class 4-5
Standard Condensate Drain
BEKOMAT®
Heatless Desiccant Dryers

Flow Rate
4 - 110 scfm
Standard Outlet PDP | Optional
-40 °F
-100 °F
Maximum Operating Pressure
232 psig (ACC 4-35)
189 psig (ACC 46-110)
Average Purge Air
18%
PN Series high pressure drains for a range of applications with hard coated drain bodies and pressure ratings up to 915 psig:
- 12 CO PN 63 / 13 CO PN 50 / 14 CO PN 25
Full stainless steel bodies with the ability to handle large volume flows and pressure ratings up to 915 psig:
- 3 E 25 / 3 E 63 / 6 E 25
Heated Desiccant Dryers

Flow Rate
4 - 110 scfm
Standard Outlet PDP | Optional
-40 °F
-100 °F
Maximum Operating Pressure
232 psig (ACC 4-35)
189 psig (ACC 46-110)
Average Purge Air
18%
Heated Purge Desiccant Dryers

Flow Rate
100 - 3200 scfm
Standard Outlet PDP | Optional
-40 °F
Maximum Inlet Air Temperature
120 °F
Maximum Operating Pressure
150 psig
Average Purge Air
7%
Membrane Dryers

Flow Rate
1 - 120 scfm
Maximum Inlet Air Temperature
140 °F at 100 psig
120 °F at 100 psig
Fixed or Adjustable Outlet Pressure Dew Point | ISO 8573-1:2010 Air Quality Class
Fixed
Class 2-6
Pre-filter Integrated to Housing
No
Standard Pipe Sizes
¼ - 1 ½”
Available Options
Wall brackets, Cover3More Extended Warranty